True R.M.S. Voltmeter 1453

Cossor, A.C.; London

  • Year
  • 1962 ?
  • Category
  • Service- or Lab Equipment
  • Radiomuseum.org ID
  • 329750

Click on the schematic thumbnail to request the schematic as a free document.

 Technical Specifications

  • Wave bands
  • - without
  • Power type and voltage
  • Alternating Current supply (AC) / 50 or 400 Hz, 110-250 Volt
  • Loudspeaker
  • - - No sound reproduction output.
  • Material
  • Metal case
  • from Radiomuseum.org
  • Model: True R.M.S. Voltmeter 1453 - Cossor, A.C.; London
  • Shape
  • Tablemodel, with any shape - general.
  • Notes
  • True R.M.S Wideband Voltmeter

    The frequency response of this instrument permits the measurement of the true R.M.S. value of white noise in the range of 50 Hz to 10 MHz. 

    The voltage coverage is 0 to 300 V in nine switched ranges.

    The instrument consists of a high frequency Vacuo-junction preceded by a high gain-stabilised wide band amplifier. Readings are indicated on a 3½” meter.

    A typical application is the quick and accurate setting of noise levels in radar receivers

  • Mentioned in
  • -- Original-techn. papers. (Electronic Engineering, volume 34, year 1962)
  • Author
  • Model page created by Pier Antonio Aluffi. See "Data change" for further contributors.