radiomuseum.org

RT655

Information - Hilfe 
ID = 49353
       
Land:
Frankreich / France
Marke: Dario (tubes) - voir aussi La Radiotechnique
Typ:  Triode (Hoch-) Vakuum   Universal 
  Ca. 1925 bis 1945, aber selten.
Identisch mit RT655
Ähnliche
Sockel anders:
  RT655_6pin
Sockel und Heizdaten anders:
  RT55
Erste Serie 1927 Saga of the Vacuum Tube, Tyne pp 404-406

Sockel Europasockel 4-Stift B4 (Eu A, E, 4A) 1914 2 Seitenanschlüsse.
Anwender Radio/TV-Empfang etc.
Heizung Uf 0.6 Volt / If 1.5 Ampere / Direkt / Spezifizierte Spannung ~ =
Beschreibung

The brandname is RT-Dario. This is an early AC tube, dated 1927.

 
Literatur - - Manufacturers Literature   not dated

f_dario_rt655_sockel.png RT655: Dépliant Dario
Mark Hippenstiel


Just Qvigstad
rt655datasmall.png
RT655: own collection
Peter den Boer † 2025

Mehr...
 

Forumsbeiträge zur Röhre
RT655
Threads: 1 | Posts: 5
Klicks: 3245     Antworten: 4
RT655, RT656, RT636, RT643
Peter den Boer † 2025
14.Nov.10
  1

I have listed these tubes as "battery". But all of these tubes has a strange low filament voltage of 0.6 Volt.The firstPhilips AC tube was the C0805 in 1926. As the designation says, the filament voltage of this tube was 0.8 Volt. This was also a direct heated tube.

Could the RT636, RT643, RT655 and RT656 be early AC types?

Peter den Boer

Jacob Roschy
17.Nov.10
  2

Hello Peter,

in the event that you have this «Radiotechnique» advertisement sheet (with these tubes in yellow) in complete condition, from which you did cut-out the data of the individual tubes, - the answer to your question might probably be found there.

If so, then please post it here completely, in order that someone can translate it.

Best Regards,

Jacob

Peter den Boer † 2025
17.Nov.10
  3

Well, my French is not that good, but the problem is that I did not look good. At the top of the attached page is printed  ... sur le réseau alternatif. Which means that these tubes are indeed AC tubes.

I also overlooked the note at the end of the page. Hier is written that these tubes have two extra side terminals. This is usual an alternative way to connect the filaments.

Sorry for the inconveniance. I will try to be more carefull.

Anlagen

Jacob Roschy
18.Nov.10
  4

Hello Peter,

thank you for posting this valuable document. It's just a I expected, «fonctionnant directement sur le réseau alternatif» means something like «works directly on AC voltage».

As for this strange filament voltage of 0.6 Volt, there might very little else to be expected.

Btw., your attached data file RT636 has no contend =(0 kb), though the first data file RT655 has all it takes.

Best Regards, Jacob

Peter den Boer † 2025
18.Nov.10
  5

Hello Jacob,

Yes there are listed two 0 kb files. But the download failed because the filzeseizes were to big (above 200Kb). I had to reduce the number of pixels te get under 200KB and keep it readable.If you are interested, hier are the other 3 pages.

Best regards, Peter

Anlagen

 
RT655
Ende Forumsbeiträge zur Röhre

[rmxtube-ge, noindex]
  